The words in your water report, in plain English

Water quality glossary

This is a plain-English glossary for your water report: limits and goals, units, treatment words and report terms. Where a term has a federal number, we show it and link the source. EPA's own pages do not define ppb or ppt in words, so we say how we read them.

Last reviewed November 20, 2026 against the cited sources.

Updated . Sources

Limits and goals

Limits, goals and levels
TermPlain meaning
MCLMaximum Contaminant Level. The highest level of a contaminant EPA allows in public drinking water. It is enforceable. Example: the PFOA and PFOS limit of 4 ppt1.
MCLGMaximum Contaminant Level Goal. The level below which there is no known or expected health risk, with a margin of safety. It is a goal, not enforceable. For PFOA and PFOS the goal is zero.
Action levelUsed for lead and copper. It is not a limit on one home. It triggers action by the utility if more than more than 10%2 of tap samples are over it. Lead is 0.015 mg/L2 (15 ppb1) and copper is 1.3 mg/L2. The lead level drops to 10 ppb2 on November 1, 20272.
MRDLMaximum Residual Disinfectant Level. The most disinfectant allowed. For chloramine and chlorine it is 4 mg/L2.
Secondary standardA non-enforceable guideline for things like taste, color and odor. Total dissolved solids has one of 500 mg/L3.
Running annual averageAn average over the last year of samples, used for byproducts and for the new PFAS limits. Florida's state agency counts a violation from the average of 4 quarterly samples4.

Units

Units you will see on a water report
TermPlain meaning
mg/L and ppmMilligrams per liter. EPA treats it as the same as ppm. A very small amount of something in water.
ppbA unit smaller than ppm, used for tiny amounts like lead. Lead's 0.015 mg/L2 action level is shown as 15 ppb1 in the city's report.
pptParts per trillion, or nanograms per liter. Smaller still. The PFOA and PFOS limit is 0.0000040 mg/L2 on EPA's page, which is 4 ppt1.
Grains per gallon (gpg)A hardness unit used for softeners. The USGS conversion is 17.118 mg/L per gpg5.
HardnessDissolved calcium and magnesium, usually shown as mg/L of calcium carbonate. USGS classes: soft is 0 to 60 mg/L6, moderately hard 61 to 120 mg/L6, hard 121 to 180 mg/L6, very hard over 180 mg/L6.
TDSTotal dissolved solids. Everything dissolved in the water, mostly minerals and salts. A taste guideline, not a health limit. See the secondary standard above.

EPA's pages that we read do not define ppb or ppt in words. We say what they mean from how EPA and the city print them.

Treatment and disinfection

Treatment words
TermPlain meaning
ChloramineA disinfectant made by adding ammonia to chlorine. It lasts longer in the pipes than chlorine alone. Boca's city water and the county's east system use it.
Free chlorineChlorine without ammonia. It disinfects faster, smells stronger and fades faster. The county switches to it for a few weeks at a time.
THMs and HAAsDisinfection byproducts. They form when the disinfectant reacts with natural material in the source water. TTHM means total trihalomethanes with a limit of 80 ppb2. HAA5 means five haloacetic acids with a limit of 60 ppb2.
NanofiltrationA membrane that pushes water through at pressure and holds back most hardness minerals and organic color. Boca uses it for part of its supply. See what is in Boca water.
Lime softeningA plant process that adds lime so hardness minerals settle out. It is the older of Boca's softening methods.
Reverse osmosis (RO)A tighter membrane at the tap that removes most dissolved things, including many PFAS. It sends some water to the drain. See reverse osmosis systems.
Activated carbonCarbon that grabs chlorine, taste and odor, and some chemicals. Catalytic carbon is a type built for chloramine.
Ion exchangeResin beads that swap one ion for another. A water softener swaps hardness for sodium or potassium. Some resins are used for PFAS in plants.
POU vs POEPoint of use treats water at one tap or fixture, such as under the sink. Point of entry, or whole-house, treats everything coming into the building. See whole house filter vs reverse osmosis.

Reports and records

Reports and records
TermPlain meaning
CCRConsumer Confidence Report. The annual water quality report your utility sends by July 17. See the city report in plain English.
UCMRUnregulated Contaminant Monitoring Rule. EPA picks contaminants with no limit yet and has utilities test for them, on a list that renews every 58. Round five tested for 30 contaminants8 and is where many PFAS results came from.
PFASA family of long-lasting man-made chemicals. PFOA and PFOS have federal limits, and the final rule covers more of them, though EPA has proposed removing the others. See PFAS in Boca Raton water.
PWSIDPublic water system ID in EPA's database. Boca's is FL4500130 PWSID9.
ViolationA record that a system missed a rule. Health-based means a limit was exceeded. A monitoring or reporting violation is paperwork: a sample or report was late or missing. See what is in Boca water.
NSF/ANSI certifiedA filter whose listed claims were tested by an outside lab. Only the claims on the certificate count. See NSF certifications.

Using this

Read your own report first. Your utility's name is on your bill. Then use the Boca report in plain English, what is in Boca water and the PFAS rules page. If a term is missing, tell us through contact.

Get a free water report for your address

Start with your ZIP. We show which utility serves it, then call you to go over its latest report and what, if anything, is worth treating.


Your home (optional)




Boca Raton Water Filtration is a trade name of Terragroupe, LLC. We book water filtration installs across Boca Raton, done by a licensed local plumber. We do not sell your details.

Questions people ask

What does ppt mean in a water report?

Parts per trillion, or nanograms per liter. Smaller still. EPA lists the PFOA and PFOS limit as 0.0000040 mg/L2, which is 4 ppt1 2.

What is the difference between an MCL and an action level?

An MCL is a hard limit on a contaminant. An action level for lead or copper is a trigger: the utility must act if more than more than 10%2 of tap samples are over it 2.

Is hard water unhealthy?

Hardness is dissolved calcium and magnesium. USGS uses it as a scale, not a health limit 6.

Sources

  1. City of Boca Raton, 2025 Annual Drinking Water Quality Report, 2026-05
  2. EPA: National Primary Drinking Water Regulations, August 31, 2026
  3. EPA: Drinking Water Regulations and Contaminants, undated (retrieved November 23, 2026)
  4. Florida DEP: PFAS regulatory updates (public water systems), May 20, 2026
  5. USGS Open-File Report 2015-1080, 2015
  6. USGS Water Science School: Hardness of Water, undated (retrieved November 23, 2026)
  7. EPA: CCR Information for Consumers, undated (retrieved November 23, 2026)
  8. EPA: Fifth Unregulated Contaminant Monitoring Rule, undated (retrieved November 23, 2026)
  9. EPA Envirofacts SDWIS violation records, PWSID FL4500130 (Boca Raton WTP), November 23, 2026
  10. EPA WaterSense Guide to Selecting Water Treatment Systems, 2024-11